Datasheet
AUIPS2041(L)(R)
www.irf.com
3
Absolute Maximum Ratings
Absolute maximum ratings indicate sustained limits beyond which damage to the device may occur. (Tj= -40°C..150°C,
Vcc=6..50V unless otherwise specified).
Symbol
Parameter
Min.
Max.
Units
Vds
Maximum drain to source voltage
-0.3
60
V
Vin
Maximum input voltage
-0.3
6
V
Isd cont.
Max diode continuous current (limited by thermal dissipation) Rth=125°C/W
1.4
A
Pd
Maximum power dissipation (internally limited by thermal protection)
W
Rth=125C°/W
1
Tj max.
Max. storage & operating temperature junction temperature
-40
150
°C
Thermal Characteristics
Symbol
Parameter
Typ.
Max.
Units
Rth1
Thermal resistance junction to ambient IPS2041L
100
°C/W
Rth2
Thermal resistance junction to ambient with 1” square footprint
50
Rth1
Thermal resistance junction to ambient IPS2041R D-Pak std. footprint
70
Rth2
Thermal resistance junction to ambient IPS2041R D-Pak 1” sqr. footprint
50
Rth3
Thermal resistance junction to case IPS2041R D-Pak
4
Recommended Operating Conditions
These values are given for a quick design. For operation outside these conditions, please consult the application notes.
Symbol
Parameter
Min.
Max.
Units
VIH
High level input voltage
4
5.5
VIL
Low level input voltage
0
0.5
Ids
Continuous drain current, Tambient=85°C, Tj=125°C, Vin=5V,Rth=100°C/W
1.4
A
Rin
Recommended resistor in series with IN pin to generate a diagnostic
0.5
5
k
Max L
Max recommended load inductance (including line inductance) (1)
10
mH
Max. t rise
Max. input rising time
1
µs
(1) Higher inductance is possible if maximum load current is limited - see figure 11