User's Manual
Technical Specifications.
NOTE that power levels and frequencies are pre-set and cannot be reconfigured or retuned by the user.
Main Battery Connection
PARAMETERS
CONDITIONS
MIN
TYP
MAX
UNITS
Charge Voltage to Battery
Sufficient Solar or EXT Power
13.8
Volt
Charge Current to Battery
“
500
mA
Current Demand from Battery
Insufficient Solar or EXT Power
5
mA
Solar Input
PARAMETERS
CONDITIONS
MIN
TYP
MAX
UNITS
Input Voltage Required
6
12
38
Volt
Current Demand from Panel
Normal Operation Average
5
mA
Backup Power Depleted
1000
EXT Power Input
PARAMETERS
CONDITIONS
MIN
TYP
MAX
UNITS
Input Voltage Required
6
12
38
Volt
Current Demand from Source
Normal Operation Average
5
mA
Backup Power Depleted
1000
Auxiliary 5V Supply
PARAMETERS
CONDITIONS
MIN
TYP
MAX
UNITS
Output Voltage
4.5
5.0
5.5
Volt
Available Output Current
Continuous
500
mA
Peak for 100 ms
5000
Auxiliary 12V Supply
PARAMETERS
CONDITIONS
MIN
TYP
MAX
UNITS
Output Voltage
11
12
13
Volt
Available Output Current
Continuous
500
mA
Peak for 100 ms
4000
Auxiliary 24V Supply
PARAMETERS
CONDITIONS
MIN
TYP
MAX
UNITS
Output Voltage
22
24
26
Volt
Available Output Current
Continuous
500
mA
Peak for 100 ms
3000