Product Manual

20
7.5 ALL CIRCUITS ON (OVERRIDE) MODE:
All Circuits On Mode will engage all electrical circuits at the same time. While short
circuit sensing is operational in this mode, if a short circuit is found, the MUTT
®
will
not be able to identify which circuit is the cause of the short. Open and crossed
circuits sensing is not operational in this mode.
On trailers using incandescent bulbs, All Circuits On Mode will typically result in an
overload because the amperage draw will exceed the maximum of 20 amps.
All Circuits On Mode can be accessed manually or by remote control.
MANUALLY
1. To activate, press and hold control knob for 10 seconds. Listen for beep, then release.
2. To cancel, press or turn the control knob.
NOTE: Does not work when ABS or Brake Light Circuits are selected.
REMOTE CONTROL
1. To activate All Circuits On Mode press and hold UP ARROW for 5 seconds and
then release.
2. To cancel, press and release either arrow.
Press and Hold UP ARROW to Activate
Press and Hold Control Knob to Activate
21
PART 8: AIR BRAKE TESTING
Complete the pretesting checklist prior to all testing procedures.
8.1 TESTING SETUP
1. Push the Power Source Switch to the OFF position.
2. Set both Emergency and Service Side Air Ball Valves to the CLOSED position.
3. Attach gladhand hoses from the MUTT
®
directly to your trailer’s air system, securing
the red hose to the Emergency Side and the blue hose to the Service Side.
4. Connect your shop air to the Shop Air Inlet on the left hand side of the tester.
5. Listen for any air leaks where the shop air connects to the tester, to avoid
erroneous results.
Set Emergency and Service Valves to CLOSED
Push Power Source Switch to OFF
Attach Gladhand Hoses
DANGER
CHOCK TRAILER WHEELS
WARNING!!! DO NOT CONNECT SHOP AIR UNTIL COMPLETING
THE TESTING SETUP PROCEDURE STEPS 1-5. FAILURE TO
FULLY UNDERSTAND THESE WARNINGS CAN RESULT IN MINOR
TO SERIOUS INJURY AND POSSIBLY DEATH.
!
!
Connect the Shop Air to the Shop Air Inlet