Product Manual
24
8.4 ACTUATING AIR BRAKES
This feature allows you to see the slacker adjustments and the pushrod travel in real
time. Brakes can be activated manually or with the remote control.
ACTUATE BRAKES MANUALLY
1. Charge the Emergency Side to the desired working pressure and leave both the
Emergency and Service Side Air Ball Valves in the OPEN position.
2. To engage the brakes, push the Service Side Brake Control Switch to
PRESSURIZE.
3. To disengage brakes, push Service Side Brake Control Switch to EXHAUST.
4. Repeat as necessary.
ACTUATE BRAKES WITH REMOTE CONTROL
1. Charge the Emergency Side to the desired working pressure.
2. With both Air Ball Valves in OPEN position, set the Service Side Brake Control
Switch to REMOTE.
3. Point the remote in the general direction of the MUTT
®
.
4. Press the ON/OFF once to engage the service air brakes.
5. Press the ON/OFF again to disengage the brakes.
6. Repeat as necessary.
Engage Brakes Disengage Brakes
Press ON/OFF Button
Set Service Side and Emergency Air Ball Valves to Open
17
7.3 FAULT INDICATION
OPEN CIRCUIT
The MUTT
®
senses no load which is often the symptom of a disconnected wire, cut
wire, poor pin connection or bad return ground. The MUTT
®
can detect open circuits
in two ways.
1. During Ground Integrity Test: An individual circuit will blink and no audible alerts
will be present.
2. During circuit selection: The selected circuit’s LED will blink, while simultaneously the
Open Circuit Indicator will fl ash. The MUTT
®
will also provide an audible alert (beep).
Example: The MUTT
®
detects an open circuit in the Clearance Light Circuit. The
Clearance LED will blink, the Open Circuit Indicator will fl ash and the MUTT
®
will beep.
NOTE: Open Circuit Indicator will only illuminate during circuit selection.
CROSSED CIRCUITS
The MUTT
®
indicates that two or more circuits are back feeding or crossed. This
can be a symptom of two wires in the same harness wearing through their insulated
coating and connecting.
1. When a crossed circuit is identifi ed, the selected circuit LED will illuminate steadily
and the circuit it is crossed with will fl ash. The MUTT
®
will also provide an audible
alert (beep).
Example: The MUTT
®
detects that the Clearance and Tail/Tag are crossed while the
Clearance Circuit is selected. The Clearance LED will illuminate, the Tail/Tag LED will
fl ash and the MUTT
®
will beep.
Example: Open Circuit in Clearance Light
Example: Crossed Circuit in Clearance and Tail/Tag Lights