7.5 ALL CIRCUITS ON (OVERRIDE) MODE:
All Circuits On Mode will engage all electrical circuits at the same time. While short
circuit sensing is operational in this mode, if a short circuit is found, the MUTT® will
not be able to identify which circuit is the cause of the short. Open and crossed
circuits sensing is not operational in this mode.
On trailers using incandescent bulbs, All Circuits On Mode will typically result in an
overload because the amperage draw will exceed the maximum of 20 amps.
All Circuits On Mode can be accessed manually or by remote control.
MANUALLY
1. To activate, press and hold control knob for 10 seconds. Listen for beep, then release.
2. To cancel, press or turn the control knob.
NOTE: Does not work when ABS or Brake Light Circuits are selected.
REMOTE CONTROL
1. To activate, press the All Circ. On button.
2. To cancel, press and release the button again.
Press and Hold Control Knob to Activate
Press and Hold ALL CIRC. ON Button