Product Manual
6
OPERATING INSTRUCTIONS
This section contains information on using the #9007 Mobile Uni-
versal Trailer Tester. (SMART MUTT®)
FUNCTIONAL DESCRIPTIONS:
The SMART MUTT® Mobile Universal Trailer Tester is a eet maintenance and
diagnostic aid for trailer electrical operations wired to North America style
congurations, including 7 round pin (tractor trailer) connections.
Fig. 2 – Control & Information Panel
A. CONTROL KNOB (Fig. 2)
Knob activates all electrical test modes and circuits to be diagnosed.
• Manual Mode • Auto cycle Mode
• Warning Sound Bypass • Small Trailer LED Mode
• Individual Circuit Select
B. VOLTAGE INDICATOR (Fig. 2)
Shows battery supply voltage integrity.
Operating Voltage: 12 Volt Voltage Cut O: 11 Volt
C. GROUND INTEGRITY (Fig. 2)
Large green LED above control knob indicates ground status.
Ground Integrity is automatically veried when power is turned on.
D. AUTO CYCLE INDICATOR (Fig. 2)
Illuminates when Auto Cycle is engaged.
Auto Cycle mode cycles through all circuits in 5 second intervals in clockwise
rotation. To enter “Auto Cycle” mode, press indicator knob once and then a
second time to stop.
E. CIRCUIT INDICATORS (Fig. 2)
The small green LEDs illuminate or blink in testing phase.
C
A
B
DEFGHJ I