Product Manual

16
OPERATING THE APP
Your Trailer Tester Application can be found on the Home Screen of the tablet. Press
the icon to launch the application. The application is designed to be intuitive and
easy to use. Review the Application Overview Guide for basic operation ow. For
technical assistance, please call 888-786-7899.
1. APPLICATION SETUP
Password-protected user accounts can be created for each tablet. To access the
Settings Menu, you must sign in as administrator. By default, the administrator
password is set as ADMIN.
2. COMPANY INFORMATION
In the Settings Menu, enter your company’s information.
3. FILE-SAVING STRUCTURE
You can choose the naming and le extension format by which the report will
save each inspection report. In the Settings Menu, choose your preferred method
le names do not get overwritten.
4. ENABLING AND DISABLING APPLICATION FEATURES
Users can decide which features of the application appear in normal testing
screens by enabling or disabling them in the Settings Menu.
See Application Overview Guide included with Tablet for more instructions.
25
8.4 ACTUATING AIR BRAKES
This feature allows you to see the slacker adjustments and the pushrod travel in real
time. Brakes can be activated manually, by remote control or with the tablet.
ACTUATE BRAKES MANUALLY
1. Charge the Emergency Side to the desired working pressure and leave both
the Emergency and Service-Side Air Ball Valves in the OPEN position.
2. To engage the brakes, push the Service-Side Brake Control Switch to
PRESSURIZE.
3. To disengage brakes, push the Service-Side Brake Control Switch to EXHAUST.
4. Repeat as necessary.
Engage Brakes Disengage Brakes
SERVICE-SIDE LEAK DOWN TESTING
1. Set the Emergency-Side and Service-Side Air Ball Valves to the OPEN position.
Set the Service-Side Brake Control Switch to the PRESSURIZE position. (This lls
the Service Side air lines.)
2. Once the Service Side is fully charged, set the Service-Side Air Ball Valve to the
CLOSED position.
3. Observe the needle on the air gauge and note any PSI drop after pressure
stabilizes.
4. Look for air loss according to your local speci cations by noting consistent air
drop over time. If air pressure continues to drop at an unacceptable rate, you can
turn your air supply back on by setting the Service-Side Air Ball Valve to OPEN
and attempt to nd the source of the leak in the air system.
Set Service-Side Air Ball Valve to CLOSED