User Manual

APPENDIX B: IP8 HPV TEST DATA SHEET
~\Technical Documentation\System Manuals\FCC-Reports\IP1HPV\IP1HPV-FCCRpt.doc Page 23
Program and Configure Radio
Date
Serial Number
Firmware Revision
Tester
Adjustment / Alignment Procedures
Receiver Injection
Parameter Spec Measured
Injection Frequency Error at
RXINJ1(within +/- 100 Hz of exact
injection frequency)
+/- 100 Hz
U34 pin 4 power level
-3 to -5 dBm
Receiver 1& 2
Parameter Spec Receiver 1
Measured
Receiver 2
Measured
RSSI test point CV1 adjustment
2.8 to 3.0 VDC
Audio DC Amplitude
(1 kHz Test tone @ 5.0 kHz
Deviation)
2.5 VDC
+/- 1mV
Audio AC Amplitude
(1 kHz Test tone @ 5.0 kHz
Deviation)
350 mVRMS
+/- 1mV
Distortion
(1 kHz Test tone @ 5.0 kHz
Deviation)
3%<
SINAD 12 dB
(1 kHz Test tone @ 5.0 kHz
Deviation)
-119dBm >