APPENDIX B: BASE STATION PARAMETERS
2003 IPMobileNet, Inc. 36 IPSeries MR User Manual / Rev. A / 04-September-03
BASE STATION PARAMETERS
Command: default gateway=xxx.xxx.xxx.xxx
Description:
When the base station is connected to the IPNC through Ethernet connection the default gateway
address must be set, otherwise it is not used.
16
Defaults: default gateway=0.0.0.0
Command: frequency = Channel number, Tx frequency, Rx frequency
Description:
Sets transmit and receive frequency for the channel. A maximum of 20 channel frequency
combinations may be entered.
17
Defaults: frequency=0, 450.125, 455.125
Command: channel=x
Description:
Where x is the channel number.
Selects the operating frequency channel
18
Defaults: channel=0
Command: hostserial=baud rate, parity, data bits, stop bits, timeout
Description:
Sets the baud rate of the serial connection. “Timeout” specifies, in milliseconds, the time to end
the frame if the end of frame character is not received.
19
Defaults: hostserial=115200, N, 8, 1, timeout=200
! Use the command unlock=password entering the appropriate password to enable programming before
issuing any commands above. Also, the base station should be reset by the “reboot” command when no
more commands will be issued.
For changes to parameters not listed in this Appendix, please contact Customer Support.