User Manual
SECTION 2: FACTORY TEST PROCEDURE
298994.DOC Page 11
Equipment List
The following table lists the equipment required to perform the IP4B Base Station Factory Test
Procedure.
CHECKLIST OF REQUIRED MATERIAL FOR
PRELIMINARY TESTING OF THE IPSeries BASE STATION
NO. REQUIRED TOOLS
;
1
Calibrated Base Station System – Consisting of the following components:
(1) Appropriate version IPSeries Base Station to be tested
(2) Desktop or laptop computer configured as an Internet Protocol Network Controller (IPNC)
(3) Corresponding IPSeries Mobile Radio (If an IP4B base station, use IP4 mobile radio)
(4) Desktop or laptop computer with two (2) available serial ports and Microsoft Windows 95 or
greater and IPMobileNet Dial-Up Networking, IPMessage software (IPMN_INVADR.exe), and
HyperTerminal for base station installed
2
Comm Test Set (HP 8920A or B)
3
High Frequency Probe (85024A)
4
Power Supply for 85024A Probe (HP1122A)
5
Four (4) Channel Scope (Tektronix TDS 460A)
6
General Purpose Scope Probe
7
Digital multi-meter Tektronix Fluke (DMM912 77)
8
DC power supply with ammeter, 13.8V, 12 amps or more (Astron VS12M or equivalent)
9
100-watt dummy load/attenuator (Pasternack PE7021-40 or equivalent)
10
Four (4) antennas (generic mag mounts) tuned to frequency or transceiver
11
Serial cable DB9M – DB9F connectors (generic)
12
Input/Output (I/O) Board (IPMN p/n: 502-80081)
13
IPSeries Base Station power cable specified for use with the specific base station being used
14
Three (3) serial DB9F-DB9M Null Modem cables