User Manual
SECTION 2: FACTORY TEST PROCEDURE
~\Technical Documentation\System Manuals\FCC-Reports\DR4B-FCCRpt.doc Page 13
Programming and Configuring the Base Station Data Radio
Once the appropriate equipment for performing the factory test are gathered, perform the following steps
to rpgoram and configure the DR4B Base Station Data Radio:
Step 1 Enter the following information on the Base Station Data Radio Performance Test Data
Sheet:
Base Station Serial number
Date test being performed
Tester’s name
Step 2 At the HyperTerminal window, type in the appropriate password and press [ENTER].
Step 3 Type ? and press [ENTER]. The following example displays in the HyperTerminal
window:
Host serial = 115200,N,8,1, timeout=200
Host framing = SLIP, no split frames no status messages
tunnel = 0
TX format = new
Injection = LOW SIDE, 45MHz
channel spacing = 25000
Channel = 0
Channel Tx freq Rx freq Inj freq
Frequency=0 , 481.000000, 486.000000, 441.000000
Serial number: yyyyyyyyy
RIM address = 1
Frequency group = 1
TX quiet time = 5
Symbol sync time = 12 milliseconds, 0 extra inter-split-frame count
TX tail time = 5
Radio data rate = 19200
Max data tx time = 60 seconds
Carrier detect delay time = 1 millisecond
Station ID = ABC123
Station ID time =10 minutes
Polarity = TX+, RX+
Allow crc errors = 0
Suppress keep alive = 0
Allow base to base = 0
Timeslot status = 0
Duplicate time = 10 milliseconds
Control head grant delay = 50 milliseconds
RIM DD delay = 0 milliseconds
Retry interval = 0 milliseconds
Retry time limit = 0 milliseconds
RSSI step = 25 (=19dBm)
IPNC = 192.168.3.3
SLIP Address = 192.168.4.6
RF IP Address = 192.168.3.1
SNTP interval = 60 seconds
num timeslots = 16
timeslot period = 992ms
timeslots per voice packet = 4
noise = -128dBm
Fixed TX Delay = 0 milliseconds
Scale TX Delay = 0 microseconds