Preliminary Test Procedure
Perform the following initial setup to prepare the base station for preliminary test:
Step 1 Connect the antenna to the base station’s TX port.
Step 2 Connect the base station to the 13.8 VDC power supply.
Step 3 Power on the base station and verify that the LED’s illuminate and the power LED on the
front panel remains illuminated.
Step 4 Verify that the base station DC-supply current is <1.2 Amps.
Step 5 For the ideal Serial or Ethernet setup please refer to the IPTurbo Converter Reference
Manual (IPMN p/n: 516.80496.REF) available on the Product Documentation CD
enclosed with this product.
Step 6 Connect the antenna to the mobile radio.
Step 7 Power on the mobile radio.
Step 8 Recycle the base station power.
Step 9 Connect the antenna to the base station’s RX1.
Step 10 Verify that the RX1 and CD LED’s are illuminated when the mobile radio is attempting to
connect. Repeat steps 9 and 10 with RX2 and RX3.
Step 11 From the mobile PC, open the DOS prompt, then ping the IPNC with the following
command:
ping 172.16.23.200 (replacing with the appropriate IPNC IP address).
Press [ENTER] and verify that the IPNC responds to the ping request. Also verify that
the base station carrier detect (CD) LED is lit followed by the TX LED.