- 18 -
Note:
The following steps 4, 5, 6 and 7 should be done on one nanoBTS and then repeated on
each remaining nanoBTS in turn.
Step 4. Calibration of nanoBTS using frequency synchronisation
Start the nanoInstaller and open a session to the nanoBTS by entering the IP address of
the nanoBTS for which the calibration is to be performed.
Figure 11 nanoInstaller opening screen
Figure 12 BTS Session
Wait until the mode and BTS status boxes indicate idle.
Once the connection is established, select the frequency band from the tool
bar.
Select, on the, Frequency Synchronisation Test icon
.
Select the NWL Properties ( ) icon and then select the ARFCN Lists tab and check
that no lists are selected.
Select the RXLEV Threshold tab and set (tick) “Apply a Threshold”.
Set the threshold to 1 to ensure a sufficiently strong signal is used for calibration.
Note:
Prior to calibration, the unit must be powered up for a minimum of 60
minutes, to ensure frequency stability.