Installation Instructions
© ip.access Ltd
COMPANY CONFIDENTIAL 110#010XA_GDE.doc
- 8 -
Status Indicator
RJ45(48Vdc)
Ethernet
TIB In
(for future
Expansion)
TIB Out (26MHz)
Figure 2 nanoBTS
The nanoBTS may be mounted on walls or ceilings, in convenient locations chosen at the system
planning stage, to provide adequate coverage in a building. Power to the nanoBTS is via the RJ45
socket enabled for 48Vdc. The nanoBTS has a LED indicator used to convey its status.
Note.
This indicator can be disabled after commissioning if required using the nanoBTS installer
software. For wall mounted installations and installations on sloping surfaces it is preferred that
the cable access is from the bottom as this prevents the ingress of dust and condensation, but
where circumstances dictate the nanoBTS may be mounted to allow cables access from the top
of the unit. When mounted on a ceiling the plastic clip-on cover
MUST
be removed to necessitate
ventilation and cooling.