Installation Instructions
© ip.access Ltd
COMPANY CONFIDENTIAL 110#010XA_GDE.doc
- 12 -
Installing the PSU at the nanoBTS.
Ensure that the PSU is placed in a location that is ventilated and that the connection leads
provide no safety hazard.
RJ45
Connection to LAN
~
PSU
48Vdc
48Vdc
!
110-230Vac
Connection to nanoBTS
Mounting the nanoBTS.
The location of each nanoBTS is shown on the installation floor plan produced at the
network planning stage. The network wiring must be complete before the nanoBTS can
be tested. The nanoBTS should be placed on a wall at or above head height or on a
ceiling.
Note: If the nanoBTS is to be used with an external antenna the nanoBTS should be
modified as shown in appendix 1
before mounting the nanoBTS
a) Fixing to a wall
1) Remove the nanoBTS from the bracket by sliding the removal tool over the central fin
between the bracket and the body of the unit to disengage the locking spring, slide
bracket to separate it from the main body of the unit. The tool may be inserted from
the top or bottom of the nanoBTS
nanoBTS bracket removal tool
Slide tool over
centre vane of
nanoBTS
Figure 5 Separating nanoBTS and mounting bracket