Installation Instructions

Table Of Contents
© ip.access Ltd
COMPANY CONFIDENTIAL CENG0336_XE_nanoBTS_Installation_and_Test_Manual.doc
- 132 -
Name Type What
DHCP
Boolean whether to run the DHCP configuration
phase
IpAddress
IP address explicit IP address to assign
IpLeaseTime
number length of IP lease in seconds
MacAddress
MAC address MAC address of BTS
Router
IP address IP address of default gateway
SubnetMask
IP address subnet mask
6.11.6 Unit ID Configuration Phase
Here is the full list of parameters relating to the Unit ID configuration phase:
Name Type What
ConfigureUnitId
Boolean whether to run the Unit ID configuration
phase
NewUnitId
unit id enter the new Unit ID value
ResetBtsUnitId
Boolean whether to reset the nanoBTS after
configuring the Unit ID
6.11.7 Non-volatile Attribute Configuration Phase
To cause a non-volatile attribute to be sent to the nanoBTS you need to switch on
both the overall "nvram" boolean parameter and a specific boolean parameter which
specifies a particular group of non-volatile attributes which are set as a unit. (These
specific boolean control parameters correspond to the various check boxes on the NV
Attr (n) tabs of the BTS Configuration dialog box, see section 6.7.)
Control parameter Settings affected
SendNvConfigFlags
NV config flags F1 to F14
SendPrimaryOmlConfig PrimaryOmlIpAddress, PrimaryOmlTcpPort,
PrimaryOmlIpAddress2, PrimaryOmlTcpPort2
SendPrimaryOmlFbTimeout PrimaryOmlFbTimeout
SendSecondaryOmlConfig SecondaryOmlIpAddress
Sendlocation
The BTS' location string as specified in the [BTS]
section header.
SendUnitName UnitName
SendSnmpConfig
All Snmp* settings (ie. Settings that start with the
characters Snmp, regardless of case)
SendAlarmThresholdList InputVoltageLower, InputVoltageUpper,
InternalTempLower, InternalTempUpper,
InputCurrentLower, InputCurrentUpper,
InputPowerLower, InputPowerUpper
So in order to persuade BTS Installer to send a unit name string to a BTS during
automatic configuration you'll need all of:
[ BTS : somewhere ]
nvram ; run the NVRAM setting procedure
sendunitname ; send the unit name parameter