nanoLTE AP Pre-Provisioning and Configuration AP-Unique Parameters
NANO_INST_43370 v101_0.4 for N4G_1.1 © ip.access Limited 2016 Page 27
4 AP-Unique Parameters
The previous section deals with all of those parameters that are in some way shared and,
thus, may be used to populate one or more templates. There remains a small set of
parameters that must be uniquely configured on a per-AP basis.
The topics in this section are:
• 4.1 Parameters for AP Identification
• 4.2 Network Names
• 4.3 AP Location
4.1 Parameters for AP Identification
Align the attributes and parameters in the following table with the naming policy. See
section 3.3 for advice on the AP naming policy.
MIB/Data Model Name Description Comment
AP info->objectInstanceId The numeric instance identifier of the
AP Info object, displayed as part of the
“Site ID” in the NOS Client.
Specified during AP
pre-provisioning
AP Info->objectname Textual ID for AP, displayed as the Site
Name in the NOS Client.
The NOS Create Site
Wizard automatically sets
this as “Site <Site ID>”.
equipmentIdentity The unique EID of an AP, composed of
the OUI and the serial number.
Used by the NOS to
identify an AP when it
connects.
Device.DeviceInfo.X_000295_
ObjectName
The user-defined name string
associated with a managed object. The
value of this parameter is used to
populate the UniqueId field of PM
report file names and the UserLabel
field of the PM file contents. Up to 50
characters excluding the following:
hash, semi-colon, equals and comma.
Optionally use this to
provide a structured,
unique name. However,
this relies on rigorous
application of this policy. It
is recommended that an
equipment ID suffix is used
ensure uniqueness
Device.FAP.PerfMgmt.Config.
{i}.X_000295_JobId
An identifier used to reference the
measurements. This may optionally be
set by the management system. If this
has been set (i.e. is not an empty
string) then this identifier is included in
all PM reports and becomes part of the
filename of the PM report. The value in
Job ID must not be set via
management system client unless the
values of [generateJobId] and
[appendEquipmentId] are set to
FALSE. If the values of [generateJobId]
and [appendEquipmentId] are set to
TRUE, Job ID is automatically
constructed and set by the
management system.
If the recommended
auto-naming policy is in
use, there is no need to
specify a value for this
parameter.
That is, only configure this
manually if the automatic
naming policies in the
jobIdConstructionPackage
in the APs object are
disabled.