User's Manual
Table Of Contents
- nano3G AP Installation Manual
- Table of Contents
- 1 Introduction
- 2 Installation Overview and Requirements
- 3 Pre-Provisioning a nano3G AP
- 4 Configuration File Preparation
- 5 Commission a nano3G AP
- 6 nano3G AP Hardware Installation
- 7 Finalize Installation
- 8 Troubleshooting
- 9 nano3G AP and PSU Regulatory Information
nano3G AP Installation Manual Commission a nano3G AP
N3G_INST_300 v14.0 for N3G_2.85 © ip.access Limited 2012 Page 40
5.3 Access the Commissioning Web Page for the AP
The commissioning web page is only accessible after performing a factory reset. The login
prompt for this web page is also only available for 60 seconds, after which the AP will
attempt to boot normally.
1) Start a web browser on the commissioning terminal.
2) In the address bar, type in the pre-defined static IP address and port number for
the web server, but do not press <Enter> yet:
http://192.168.0.1:8089
3) Perform a factory reset on the AP:
• Press and hold the reset button. Initially, the service LED blinks rapidly.
• When the service LED changes from blinking rapidly to blinking slowly,
release the reset button.
• The LED continues to flash slowly until the factory reset completes, at which
point the LED is extinguished and the AP reboots.
Note: See section 8.3 for more information about factory reset.
4) Wait a few seconds, then press <Enter> in the web browser. A login screen should
appear. If the login screen does not appear immediately, refresh the browser
screen until it appears.
ALERT: When the AP starts up, the login prompt for the commissioning web
page is only available for 60 seconds. If the login prompt is missed,
press the reset button to repeat the factory reset.
5) Enter the commissioning user name and the password (supplied separately for
security reasons).