8.1 Appendix A - Example AP Configuration File
A configuration file with the object name and the objects instance (relative distinguished
name) must be created for each AP to be commissioned. For instructions to use the
configuration file, see section 5.3.
The file has
to conform to the following syntax:
all non-comment lines are of the form <name>=<value>
comment lines begin with the hash character (#)
attribute types are as follows:
o integer tos=0
o enumeration t300=T300_4000_MSEC
o array ascPersistenceScalingFactors=[6,6,6,6,6,6]
o boolean soipHeartbeatEnabled=true
o structure cellBroadcastMessage={50,GSM_DEFAULT,”oyster 3G”}
o string “HMAC-SHA1”
o set alarmFilter=()
# Instance for the AP to be modified
Object=apNano_001
ObjectInstance=ROOT#0;AC_CONNECTION#12007;RNS#0;AP_CONTROLLER#
0;AP_CONNECTION#31;AP#0
# Cell Package
rncIdentity=139
# NAS Package
mcc="159"
mnc="12"
sac=1
saiLac=1
# Network Listen Control Package
lacRacCandidateList=({15912,(99)})
rfParamsCandidateList=({1062,437,1})
rssiScanBands=({BAND_NAME_UMTS_BAND_04_NO_SPOT,()})
# end of file
Parameter Description
Object
ID of the AP