User's Manual

Table Of Contents
nano3G AP Installation Manual Commission a nano3G AP
N3G_INST_300 v6.3 for N3G_2.0 © ip.access Limited 2010 Page 27
4 Commission a nano3G AP
This procedure provisions the nano3G AP with the settings it needs to establish a
connection with its serving nano3G AC. Once commissioning is complete, use the OMC-R
Client for further configuration and to bring the AP into service.
An AP can be commissioned in advance of the site visit or can be commissioned on site via
a provisioning laptop. This procedure assumes on-site provisioning with a laptop.
The nano3G AP must be in the factory reset state for this procedure. If a factory reset is
required, see section 7.2 for instructions.
4.1 Configure a Provisioning Laptop to Connect to the AP
1) Connect the AP and the provisioning laptop with an Ethernet cable.
2) Open the Windows Control Panel on the laptop.
3) Go to Network Connections.
4) Right-click the relevant Local Area Connection and select Properties.
5) In the list of items on the General tab, select Internet Protocol (TCP/IP) and then
click Properties. The following dialogue appears:
6) If it is not possible to leave this network connection permanently configured for AP
commissioning, make a note of the current settings.
7) Click the Use the following IP address radio button.
8) Set the IP Address to 192.168.0.2.
9) Set the Subnet Mask to 255.255.255.0.
10) There is no default gateway, so ensure the default gateway address is cleared.
11) Click OK to close and save the changes in each of the two dialogues. Also close
the Control Panel.