SDS
Page 8 of 17
Report No.: PN2021091532701
Shenzhen NTEK New Energy Technology Co., Ltd.
Tel: +86(0)-755-3699 5529 http://www.ntekbat.org.cn RE-039 A/0
Nom chimique
ACGIH TLV
ACGIH TLV
ACGIH TLV
Nickel
7440-02-0
TWA: 1.5 mg/m³
TWA: 1 mg/m³
(vacated) TWA: 1 mg/m³
IDLH: 10 mg/m³
TWA: 0.015 mg/m³
Nickel Hydroxide
12054-48-7
TWA: 0.2 mg/m³ Ni
inhalable fraction
TWA: 1 mg/m³ Ni
(vacated) TWA: 1
mg/m³ Ni
IDLH: 10 mg/m³ Ni
TWA: 0.015 mg/m³ except
Nickel carbonyl Ni
Cobalt oxide
11104-61-3
TWA: 0.02 mg/m³ Co
Potassium hydroxide
1310-58-3
TWA: 0.2 mg/m³
(vacated) Ceiling:
2mg/m³
Ceiling: 2 mg/m³
*ACGIH TLV: American Conference of Governmental Industrial Hygienists - Threshold Limit Value OSHA
PEL: Occupational Safety and Health Administration - Permissible Exposure Limits NIOSH IDLH Immediately
Dangerous to Life or Health
ACGIH TLV: American Conference of Governmental Industrial Hygienists - Threshold Limit Value OSHA PEL:
Occupational Safety and Health Administration - Limites d'exposition admissibles immédiatement dangereuses pour
la vie ou la santé
Other Exposure Guidelines
Autres lignes directrices surl'exposition
Vacated limits revoked by the Court of Appeals decision in AFL-CIO v. OSHA, 965 F.2d 962
(11th Cir., 1992) See section 15 for national exposure control parameters
Limites libérées révoquées par la décision de la Cour d'appel dans l'affaireAFL-CIO c. OSHA, 965 F.2d 962 (11e cir., 1992) Voir l'article
15 des parameters nationaux de contrôle de l'exposition
Appropriate engineering
controls
Contrôles techniques
appropriés
Engineering Measures:
Mesures techniques
Showers
Douches
Eyewash stations
Stations de lavage des yeux
Ventilation systems.
Systèmes de ventilation
Individual protection
measures, such as personal
protective equipment Mesures
de protection individuelles, telles que
l'équipement de protection individuelle
Eye/Face Protection Protection oeil/visage: No special protective
equipment required. Aucun équipement de protection spécial n’est
nécessaire.
Skin and Body Protection Protection de la peau et du corps: No special
protective equipment required. Aucun équipement de protection spécial
n’est nécessaire.
Respiratory Protection Protection respiratoire: No protective equipment is
needed under normal use conditions. If exposure limits are exceeded or
irritation is experienced, ventilation and evacuation may be required.
Aucun équipement de protection n'est nécessaire dans des conditions
d'utilisation normales. Si les limites d'exposition sont dépassées ou si l'irritation est
ressentie, une ventilation et une évacuation peuvent être nécessaires.
Hygiene Measures Mesures d'hygiène: Handle in accordance with good
industrial hygiene and safety practice. Poignée conformément aux bonnes
pratiques d'hygiène et de sécurité.
Section 9 - Physical and Chemical Properties