Iota Charger Ratings

DLS RATINGS AND SPECIFICATIONS
REV 042412
IOTA ENGINEERING PO BOX 11846 TUCSON, AZ 85734 TEL: 1-800-866-IOTA (4682) FAX: (520) 741-2837 WEB: www.iotaengineering.com
CORD CONFIGURATION
DLS-240
SERIES M
240VAC DLS
CONVERTERS/CHARGERS
DC Output Voltage
(No Load) approx.
Output Voltage Tolerance
(No Load)
Output Amperage,
Max Continuous
Output Voltage
(Full Load) approx.
Maximum Power Output,
Continuous
Ripple and Noise
Input Voltage Range
Input Voltage Frequency
Maximum AC Current (@216Vac)
Typical Efficiency
Max Inrush Current, Single Cycle
Short Circuit Protection
Overload Protection
Line Regulation
Load Regulation
Fan Control
Thermal Protection
Working Temperature Range
Storage Temperature
Withstand Voltage (VDC)**
Approximate Dimensions
Weight
13.6V (DC)
+ or - .7%
30 Amps
>13.4V (DC)
400 Watts
<50 mV rms
216-264 AC
47-63
3.7 Amps
>80%
30 Amps
Ye s
>100%
100 mV rms
<1%
PROPORTIONAL
YES
0° - 40° C
-20° to 80° C
1700/1700/500
9.7 x 6.7 x 3.4
5.0 lbs
13.6V (DC)
+ or - .7%
45 Amps
>13.4V (DC)
600 Watts
<50 mV rms
216-264 AC
47-63
5.5 Amps
>80%
30 Amps
Ye s
>100%
100 mV rms
<1%
PROPORTIONAL
YES
0° - 40° C
-20° to 80° C
1700/1700/500
9.7 x 6.7 x 3.4
5.0 lbs
13.6V (DC)
+ or - .7%
55 Amps
>13.4V (DC)
750 Watts
<50 mV rms
216-264 AC
47-63
6.7 Amps
>80%
30 Amps
Ye s
>100%
100 mV rms
<1%
PROPORTIONAL
YES
0° - 40° C
-20° to 80° C
1700/1700/500
9.7 x 6.7 x 3.4
5.0 lbs
SERIES M SERIES M SERIES M
RATINGS AND
SPECIFICATIONS
DLS-
240-30
DLS-
240-45
DLS-
240-55
27.2V (DC)
+ or - .7%
40 Amps
>27.0V (DC)
1100 Watts
<100 mV rms
216-264 AC
47-63
10.0 Amps
>80%
40 Amps
Ye s
>100%
100 mV rms
<1%
PROPORTIONAL
YES
0° - 40° C
-20° to 80° C
1700/1700/500
13 x 6.5 x 3.4
7.8 lbs
DLS-
240-27-40*
DLS-
240-54-20*
**Primary to Chassis/Primary to Secondary/Secondary to Chassis
54.4V (DC)
+ or - .7%
20 Amps
>54.2V (DC)
1100 Watts
<100 mV rms
216-264 AC
47-63
10 Amps
>80%
40 Amps
Ye s
>100%
100 mV rms
<1%
PROPORTIONAL
YES
0° - 40° C
-20° to 80° C
1700/1700/500
13 x 6.5 x 3.4
7.8 lbs
*Unit is not UL Listed
Specific IOTA 240VAC DLS converter/chargers are
supplied with a power cord (approx. 36 inch length) for
connection to the AC input. Plug type on the cord is
determined by the input voltage and ratings of the DLS
model and/or UL specifications.
NOTE: DLS-240-27-40 and DLS-240-54-20 models
feature a standard IEC receptacle for inserting an AC
power cord (not supplied). Always use an appropriately
rated cord (at least 16 gauge or 13mm
2
) for connection
to the AC input.