User's Manual
WA020100 - Smart Irrigation Controller
UMAOC001 Rev G
USER MANUAL
Page 23 of 33
7.2.5 DOWNLINK 06 – NEXT DATA REQUESTED FOR UPLINK
By default Watersens performs uplinks with the status parameters of the device. If it is needed another
type of info, it could be requested with the downlink specified below
byte 1
byte 2
byte 3
tf
nu
ev
tf. Type of frame (06 - Next data requested for uplink)
nu. Data Type for next uplink:
00 - Watersens parameters status
01 - Irrigation schedule of the electrovalve specified in ev byte
03 - Uplink period
05 - LoRaWAN Network status
ev. Electrovalve requested (only necessary to request irrigation schedule)
Examples
· To know the network status, send to Watersens the downlink payload
(tf = 06 / nu = 05 / ev not required) - 06 05
· To know the irrigation schedule of electrovalve connected to output 2, send to
Watersens the downlink payload
(tf = 06 / nu = 01 / ev = 02) - 06 01 02
NOTE
• After sending the requested data (different from device status), the Watersens will send again
the device status