Contactors, Relays and Solenoids
As a safety precaution an external power disconnect device should be used. A disconnect such as a contactor, relay or
solenoid with the proper ratings for the planned load. The disconnect devices contacts should be rated for the total current
output of both motor channels combined. The disconnect device can be controlled by the DOUT pins or a simple manual
switch. The DOUT pins are designed to control inductive loads. They can be toggled by users commands. The wiring diagram
below illustrates a basic wire scheme using a relay as a disconnect for the main power. The DOUT controls the ground to the
relay coil. The positive terminal of the relay coil can be connected several ways depending on its rated voltage. The diagram
below shows a 12VDC logic battery and a 12VDC Relay. If the relay coil is 5VDC the regulated user output (BEC) could be
used instead. The main battery can also be the power source provided a logic battery is present.
+
-
Battery
Motor 1
Motor 2
R1
F1
D1
M1A
M1B
M2B
M2A
B-
B+
ROBOCLAW
F2
-
+
Logic
Battery
RY1
SW2
LB+
GND
LB+
DOUT