1.8 Bridged Channel Mode
1.8.1 Bridging Channels
The dual channels on an MCP can be bridged to run as one channel, effectively doubling its
current capability for one motor. The MCP can be damaged if it is not set to bridged channel
mode before wiring up the single motor as show. Download and install Ion Studio setup utility.
Connect the motor controller to the computer using an available USB port. Run Ion Studio and
in general settings check the option to bridge channels. Then click “Save Settings” in the device
menu. When operating in bridged channel mode the total peak current output is combined from
both channels. The peak current run time is dependant on heat build up. Adequate cooling must
be maintained.
1.8.2 Bridged Channel Wiring
When bridged channel mode is active the internal driver scheme for the output stage is modied.
The output leads must be wired correctly or damage will result.