58 - Set Logic Battery Voltages
Set the Logic Battery Voltages cutoffs, Min and Max. Min and Max voltages are in 10th of a volt
increments. Multiply the voltage to set by 10.
Send: [Address, 58, Min(2 bytes), Max(2bytes, CRC(2 bytes)]
Receive: [0xFF]
59 - Read Main Battery Voltage Settings
Read the Main Battery Voltage Settings. The voltage is calculated by dividing the value by 10
Send: [Address, 59]
Receive: [Min(2 bytes), Max(2 bytes), CRC(2 bytes)]
60 - Read Logic Battery Voltage Settings
Read the Logic Battery Voltage Settings. The voltage is calculated by dividing the value by 10
Send: [Address, 60]
Receive: [Min(2 bytes), Max(2 bytes), CRC(2 bytes)]
80 - Restore Defaults
Reset Settings to factory defaults.
Send: [Address, 80, CRC(2 bytes)]
Receive: [0xFF]
82 - Read Temperature
Read the board temperature. Value returned is in 10ths of degrees.
Send: [Address, 82]
Receive: [Temperature(2 bytes), CRC(2 bytes)]
83 - Read Temperature 2
Read the second board temperature(only on supported units). Value returned is in 10ths of
degrees.
Send: [Address, 83]
Receive: [Temperature(2 bytes), CRC(2 bytes)]