1.9.9 DOUTx
The DOUTx pins are sinking only. They can be used to drive loads such as contactors or braking sys-
tems. Conî‚¿gure the MCP digital output pins.
Mode
Sets the action that will trigger the output pin. MCL scripts can override the set action
Motor1 On - Turns the selected DOUTx pin on when motor channel 1 turns on.
Motor2 On - Turns the selected DOUTx pin on when motor channel 2 turns on.
Motors On - Turns the selected DOUTx pin on when either motor channel turns on.
Motor 1 Reverse - Turns the selected DOUTx pin on when motor channel 1 reverses
direction.
Motor 1 Reverse - Turns the selected DOUTx pin on when motor channel 1 reverses
direction.
Motors Reverse - Turns the selected DOUTx pin on when either motor channel reverses
direction.
Over Voltage - Turns the selected DOUTx pin on when the motor controller has an over
voltage condition.