Instruction Manual
Table Of Contents
- Glossary of terms
- 1. This manual
- 2. Safety
- 3. Get to know SBV System Series
- 4. Functioning principles
- 4.1 Sensor functioning principles
- 4.2 Detection fields
- 4.3 Safety working modes and safety functions
- 4.4 Safety working mode: Both (default)
- 4.5 Safety working mode: Always access detection
- 4.6 Safety working mode: Always restart prevention
- 4.7 Restart prevention function: static object detection option
- 4.8 Features of the restart prevention function
- 4.9 Muting
- 4.10 Anti-tampering functions: anti-rotation around axes
- 4.11 Anti-tampering functions: anti-masking
- 5. Sensor position
- 6. Installation and use procedures
- 7. Maintenance and troubleshooting
- 8. Technical references
- 9. Appendix
72
SBV System Series| Instruction manual v1.2 DEC 2021 |SAF-UM-SBVBus-en-v1.2|© 2021 Inxpect SpA
7. Maintenance and troubleshooting
distance (in mm) and the detection angle (°). See "Verbosity level for detection access and exit events" on
page70
Format: Detection access (field #n, distance mm/azimuth°)
Example:
20 2020/11/18 16:47:25 [INFO] SENSOR #1 Detection access (field #1, 1200 mm/30°)
7.3.7 Detection exit
After at least one detection access event, a detection exit event related to the same field is logged when the
detection signal returns to its default no-motion status.
Depending on the selected verbosity level additional parameters are logged: the detection field number, the
sensor which detected the motion.
Format: Detection exit (field #n)
Example:
20 2020/11/18 16:47:25 [INFO] CONTROL UNIT Detection exit (field #1)
7.3.8 Dynamic configuration in use
At every change of the dynamic configuration, the new ID of the dynamic configuration selected is logged.
Format: Dynamic configuration #1
Example:
20 2020/11/18 16:47:25 [INFO] CONTROL UNIT Dynamic configuration #1
7.3.9 Muting status
Every change of the muting status of each sensor is logged as disabled or enabled.
Note: the event indicates a change of the muting status of the system. It does not correspond to the muting
request.
Format: Muting disabled/enabled
Example:
20 2020/11/18 16:47:25 [INFO] SENSOR#1 Muting enabled
7.3.10 Fieldbus connection
The Fieldbus communication status is logged as CONNECTED, DISCONNECTED or FAULT.
Format: Fieldbus connection CONNECTED/DISCONNECTED/FAULT
Example:
20 2020/11/18 16:47:25 [INFO] CONTROL UNIT Fieldbus connection CONNECTED
7.3.11 Modbus connection
The Modbus communication status is logged as CONNECTED or DISCONNECTED.
Format: Modbus connection CONNECTED/DISCONNECTED
Example:
20 2020/11/18 16:47:25 [INFO] CONTROL UNIT Modbus connection CONNECTED