Instruction Manual

Table Of Contents
58
SBV System Series| Instruction manual v1.2 DEC 2021 |SAF-UM-SBVBus-en-v1.2|© 2021 Inxpect SpA
6. Installation and use procedures
3. Click Settings > Node IDAssignment.
4. Proceed according to the type of assignment:
If the assignment is... Then...
manual 1. Click DISCOVERCONNECTEDSENSORS to display the connected
sensors.
2. To assign a Node ID, click Assign for the unassigned Node ID in the
Configured sensors list.
3. To change a Node ID, click Change for the already assigned Node ID
in the Configured sensors list.
4. Select the SIDof the sensor and confirm.
automatic 1. Click DISCOVERCONNECTEDSENSORS to display the connected
sensors.
2. Click ASSIGN NODE IDS > Automatic.
semi-automatic Click ASSIGN NODE IDS > Semi-automatic and follow the instructions
displayed.
6.2.10 Chain examples
Chain with control unit at the end of the chain and a sensor with bus terminator
Chain with control unit inside the chain and two sensors with bus terminator
6.2.11 Save and print the configuration
1. In the application, click APPLY CHANGES: the sensors will save the inclination set and the surrounding
environment. The application will transfer the configuration to the control unit, and once transfer is complete
it will generate a configuration report.
2. Click to save and print the report.
3. Ask the authorized person for a signature.
6.2.12 Set the control unit Ethernet parameters
1. Ensure the control unit is turned on.
2. Press the Network parameter reset button and hold it down during steps 3 and 4.
3. Wait for five seconds.