Installation Guide

D
AC:
INVIXIUM recommends a separate power supply for Door Strike (not included) for this configuration
Snubber Diode required for Door Strike (not included)
Example above shows use of RLY_NO, but RLY_NC may be used instead if required by the Door Strike
Internal Relay rated upto max of 1A @ 24VDC
For motion detector instead of Request-to-Exit-buttom, connect the following signals:
(1) DAC_OUT to the COM and (2) DAC_IN2 to the Relay NO of the motion detector
Door Access Control Connections for MYCRO, MERGE, SENSE, TOUCH, SENSE 2 and TOUCH 2
R
LY_NO
DAC_IN1
RLY_COM
DAC_OUT
DAC_OUT
DAC_IN2
Snubber Diode
Door Strike
Door Contact
Request to exit
T
OUCH 2
DAC Connections
RLY_NC
RLY_COM
RLY_NO
DAC_IN1
DAC_IN2
DAC_OUT
3
4
*
Max Relay Rating = 1 Amp @ 24 VDC
D
oor Strike Power Supply
C
opyright 2019
INVIXIUM