Users Manual

PN17TR 915MHz Transceiver Module Inventis Technology Pty Ltd
Unit 4, 2 Southridge St. Eastern Creek NSW, Australia Page 11
0 (0000)
1 (0001)
2 (0010)
3 (0011)
4 (0100)
5 (0101)
6 (0110)
7 (0111)
8 (1000)
9 (1001)
10 (1010)
11 (1011)
12 (1100)
13 (1101)
14 (1110)
15 (1111)
61
57
53
49
45
41
37
33
29
25
21
17
13
9
5
1
4
8
12
16
20
24
28
32
36
40
44
48
52
56
60
64
0x04: SYNC1 Sync Word, High Byte
Bit
Field Name
Reset
R/W
Description
7:0
SYNC[15:8]
211 (0xD3)
R/W
8 MSB of 16-bit sync word
0x05: SYNC0 Sync Word, Low Byte
Bit
Field Name
Reset
R/W
Description
7:0
SYNC[7:0]
145 (0x91)
R/W
8 LSB of 16-bit sync word
0x06: PKTLEN Packet Length
Bit
Field Name
Reset
R/W
Description
7:0
PACKET_LENGTH
255 (0xFF)
R/W
Indicates the packet length when fixed packet length
mode is enabled. If variable packet length mode is
used, this value indicates the maximum packet
length allowed. This value must be different from 0.
0x07: PKTCTRL1 Packet Automation Control
Bit
Field Name
Reset
R/W
Description
7:5
PQT[2:0]
0 (0x00)
R/W
Preamble quality estimator threshold. The preamble
quality estimator
increases an internal counter by one each time a bit
is received that is different from the previous bit,
and decreases the counter by 8 each time a bit is
received that is the same as the last bit.
A threshold of 4∙PQT for this counter is used to gate
sync word detection.When PQT=0 a sync word is
always accepted.