User's Manual

WIRING
8/6/02 PRELIMINARY DOCUMENT 5
Note: In four-wire 240 VAC configuration, the neutral wire is not connected to the LCM.
TABLE 3. Wiring Chart
FIGURE 4. Installation wiring connections for a 120 and 240 VAC application
3. When wiring is complete reinstall cover (see Mounting on page 3) and apply power
to the LCM and the electrical appliance.
LCM Style Bottom Terminal Center Terminal Top Terminal
vL02606100 Ground (green) Neutral (white) Hot (black)
vL02606200 Ground (green or bare) L2 (red) L1 (black)
L1
L1
240 VAC
L2/N L2/N
EARTH EARTH
L1
L1
120 VAC
L2/N L2/N
EARTH EARTH
GROUND
NEUTRAL
HOT
BLACK
WHITE
GREEN
GROUND
LINE 2
LINE 1
BLACK
RED
GREEN OR BARE
120 VAC SYSTEM WIRING 240 VAC SYSTEM WIRING