2. Main features
2.1 Main Functions
Compatible with the protocol standards of ISO18000-6C (EPC global UHF
Class 1 Gen 2), and the performance of reading and writing tags is excellent.
By matching the application software, the corresponding label information
can be established.
Support multi-tag reading. 20 Tags can be read by default, and supports more
label reading by increasing power.
2.2 Main technical parameters
Frequency band: 920.25
MHz–927.25MHz
RF output power
0dBm
27dBm
stepping 1dB, power selectable
Air interface protocol
Support EPC global UHF Class 1 Gen 2 / ISO
18000-6C
Read label EPC code rate
≥140 pieces/S
Readingdistance
0
50cm
Writing distance
0
50cm
Misreading range
10cm
Baud rate
115200bps
Maximum operating current
1.5A
Operating temperature
-10
℃~
+55
Storage temperature
-15
℃~
+60
Humidity range
10%
90% RH
no condensation
2. Main features
User Manual
XC-RF855 Reader
8
The reader is xed rmly, no loosening
Screws tightened.
5.6.2 Performance acceptance
Mainly from two aspects to check whether the reader is working normally
Check whether the reader is working properly.
Check the range of reading and writing to meet the requirements.
20 tags can be read at the same time by default
The reading range on top of the
cover is not less than 50cm
The misreading area around the metal frame is no
more than 10cm
When testing, it is recommended to ip the label carrier.
5. Installation and Commissioning