a) Connect your power supply to the provided 2-ways connector respecting the
wiring described above.
b) Connect the reader to the host system using Ethernet.
c) Connect one or several antennas to reader channels.
d) Connect the power supply to the mains supply.
4.3 Using 10/100 Ethernet Inteace
10/100 Ethernet interface does not require specific drivers installation. Default
TCP/IP conguration is the following:
Table 4.1:Default TCP/IP conguration
Parameter Value
DHCP
Active (The reader will t to automatically congure
using DHCP. If it fails, the reader will use the following
fallback conguration)
Fallback IP Address 192.168.9.23
Fallback Netmask 255.255.255.0
Fallback Gateway 192.168.9.1
Hostname
XC-RF300-XX-XX-XX (where XX-XX-XX is the last 3
hex couples of the reader MAC address)
The MAC address of each reader is written on a sticker positioned at the bottom
right corner of the reader.