User's Manual
XCRF-860 USER’S MANUAL
32
Fig. 6.15 Reader’s Operating Frequency Configuration
3. Configuration of Multiple Readers Operation
As illustrated in Fig. 6.16, if two or more readers operate in
proximity, the instructions below must be followed during
installation and commissioning, so as to eliminating interference
to each other.
1. The minimum distance of the centers of the antennas of two
adjacent readers must be 3m;
2. The operating frequencies of two adjacent readers must be
respectively configured as “Default A” and “Default B”.