User's Manual

16 
XCRF-500 reader:
(1) Make sure that the voltage is AC100V ~ 240V and working
frequency is 50Hz;
(2) Make sure that the switch of XCRF-500 reader series is off;
(3) Plug one end of the power line into the socket of AC power
supply, and another end into the triple-cored-cassette AC
power input of XCRF-500 reader series
(4) Turn on the switch on the front panel of XCRF-500 reader
series. After a beep, power supply indicator lights up, then
the reader is initialising, and the system is standby after
finishing initialising process.
Note:
When XCRF-500 reader is in default status, the system is in
standby status after start- up. The reader does not transmit radio
wave when it is initialising or standby (radio power amplifier is
off). Only after connected to antenna or load and receiving
Read/Write tag’ command from PC or Enable Power
Amplifier command, Power Amplifier of reader turns to
working status.
Caution: It is harmful for readers to enable the Power
Amplifier with the absence of the connection to antenna or