User's Manual

ID length: The length of TID data memory section to be read, measured in bytes.
Userdata offset: The offset address of user data memory section, measured in byte.
Userdata length: The length of user data, measured in bytes.
OK: perform the settings and return to the interface of read settings.
l Tag Amount: to set the max amount of tags covered by the radio signal.
l Read interval: to set the interval of reading tags, measured in 10 milliseconds.
l TID Length: to set the length of TID data memory section that will be read.
l Tag Type: to select the tag type (6C, 6B or 6C/6B).
l Stop Condition:
Read Time: tick to set the reading time period (10 seconds to 300 seconds). If there are no
tags to be read in the period, the reader will stop scanning afterward. Otherwise, scanning
will not be stopped automatically.
Tag amount: tick to set how many tags to be scanned. The reader will stop after the same
numbers of tags have been read.
You can click button Stop on the RFID interface to or press the key SCAN on the device
to stop reading. You can also press the yellow key on the left side of the device to stop
reading.
l Sound: tick to open the prompt sound.
l RSSI: tick to display RSSI.
l Char. Display: tick to display read data in characters.
l OK: to perform the settings.
2.2.3 Read/Write tag
Path: RFID --> Option --> Read/Write tag
Settings: If the RFID interface has got the read data of tags, you could set the tag reading or writing
settings for each tag on this interface as shown in figure 2-7.
Figure 2-7 Read/Write tag
l Drop-down list: to select a tag to operate.
l Offset: to set the beginning address for operation.
l Length: to set the data length for operation.
l Access password: to enter the correct access password