User's Manual
Only the tags matching these conditions can be scanned.
2.2.11 Data Set
Path: RFID --> Option --> Data Set
Settings: save or upload tag data to specified PC. The interface is as shown in figure 2-17.
Figure 2-17 Data configuration
l Save data: tick to perform save data operation. The operation is to save tag data to the file
system of the reader. You can click button “Cache data” to view or process saved data (please
refer to details below).
l Upload data: tick to perform upload operation. The operation is to save data to the PC which is
running data receiving software. Please enter the IP address of that PC and the port monitored
by data receiving software running on that PC (please refer to chapter data receiving software).
l Interval: to set the interval of saving data, measured by milliseconds. The value works providing
that “Sava data” or “Upload data” is ticked.
l IP Address: the IP address of PC which receives uploaded data. The address works providing that
“Upload data” is ticked.
l Port: the port monitored by data receiving software running on the PC which receives uploaded
data. The port works providing that “Upload data” is ticked.
l OK: to perform the settings.
l Cache data: to click to jump into another interface shown as figure 2-18.