User's Manual

User’s Manual
XC-RF812 Reader
17
6 Operating RFID Demo
6.4.2 Reader Conguration
On the “Reader Cong” screen, user can set reader conguration parameters,
such as communication parameters (reader address, and baud rate), RFID
parameters (RF port power adjustment), and intelligent sleep mode, and perform
some basic tests.
The reader must be properly connected before you begin to congure the reader.
Click on the “Reader Cong”, and screen appears.
Figure 6-12
1, Reader address setting, and query
First, connect the reader to the host computer via USB connection, and click
the pop-up “reader conguration” dialog box on “Reader Cong”, as shown in
“1” of Figure 6-12”. Input reader IP information, including IP address, subnet
mask, and gateway. Click on the “Cong”. Click on the “Query” to get network
information.
2, Serial port baud rate setting, and query
As shown in “2” of Figure 6-12”, click on the drop-down box to select the
required parameter of “baud rate (115200bps, 19200bps, and 9600bps)”, and
then click on the “Cong”. Click on the “Query” to get baud rate (information.
3, RF port power settings, and query
As shown in “3” of Figure 6-12”, click on the drop-down box to select the