User's Manual
User’s Manual
XC-RF812 Reader
9
5 Installation and Troubleshooting
192.168.0.210) to create network connection. Check the USB driver is installed
to use USB connectivity.
5.2.2 Apply power to the XC-RF812
Apply power to the XC-RF812 reader by following steps:
● Check that the AC input voltage and operating frequency to meet the
requirements: AC 100-240V input, 50-60Hz;
● Check the adapter output voltage is 5V / 2A;
● Check the power supply connection are correct and secure;
● After applying power to the reader, wait about 10 seconds. The power /
work LED will is ashing, and the reader will play two sounds. The reader
will enter initialization state, and the system enters standby mode when
initialization process is completed.
After booting the system, the XC-RF812 reader, by default, is in
standby mode. The reader does not transmit power in the initialization
and standby mode (RF power amplier is turned off), and only operates
after receiving “read tag” command from the PC or “open amplier”
command.
5.3 Troubleshooting
This section describes troubleshooting common problems, in particular, the
general problems occur when the installation is not correct, and explains how to
correct it.
Troubleshooting common issues:
● Reader does not respond
○ Power indicator LED is on → check the relevant cable connections, and
check the corresponding items in accordance with the state of the relevant
LED indicators;
○ Network communication status → check the connection IP is correct;
check if there is an IP address conict;
● Read / write tag error
○ Check the reader type on application software is congured correctly;
○ Check if reader and tag is compatible;
○ Check tag placement, and if tag is present is reader eld;