User's Manual

User’s Manual
XC-RF812 Reader
9
5 Installation and Troubleshooting
192.168.0.210) to create network connection. Check the USB driver is installed
to use USB connectivity.
5.2.2 Apply power to the XC-RF812
Apply power to the XC-RF812 reader by following steps:
Check that the AC input voltage and operating frequency to meet the
requirements: AC 100-240V input, 50-60Hz;
Check the adapter output voltage is 5V / 2A;
Check the power supply connection are correct and secure;
After applying power to the reader, wait about 10 seconds. The power /
work LED will is ashing, and the reader will play two sounds. The reader
will enter initialization state, and the system enters standby mode when
initialization process is completed.
After booting the system, the XC-RF812 reader, by default, is in
standby mode. The reader does not transmit power in the initialization
and standby mode (RF power amplier is turned off), and only operates
after receiving “read tag” command from the PC or “open amplier”
command.
5.3 Troubleshooting
This section describes troubleshooting common problems, in particular, the
general problems occur when the installation is not correct, and explains how to
correct it.
Troubleshooting common issues:
Reader does not respond
Power indicator LED is on → check the relevant cable connections, and
check the corresponding items in accordance with the state of the relevant
LED indicators;
Network communication status → check the connection IP is correct;
check if there is an IP address conict;
Read / write tag error
Check the reader type on application software is congured correctly;
Check if reader and tag is compatible;
Check tag placement, and if tag is present is reader eld;