5.6 People Counter & Buzzer Sound Management
5.6.1 Resetting the Counter Display
Figure 5.29: LSP3A People Counter & Detection Cells Location
To reset the LCD display use a pointed element (for example: a paper clip). Insert it in the
hole on the right of the display window and press (not too hard) until you get zero displayed. This
will also reset the battery backed-up counter.
5.6.2
Resetting the Remote People Counter
See section 5.5.3.6 People Counter of Monitoring Pedestal Activity for moreinformation.
5.6.3
Adjusting the Level of the Buzzer Sound
Using a flat headed 4mm screw driver (less than 4mm max diameter) through the outermost
left hole, adjust the buzzer sound to the desired level turning clockwise or anticlockwise.
To trigger the alarm during the trimming operation, either use a book with an EAS set label or
depress the Test Button on the Basic Configuration Tab of the LSP3A Configuration Tool.