In the “Alarm Duration” section:
Select the alarm duration in the drop-list.
Click “Test” to trigger an alarm (this is useful either to test alarm duration, or to identify the
pedestal you’re connected to).
5.5.3.3 Sycn mode
Figure 5.13: Sync setting
In the “Synchro” section:
Select whether the pedestal is to be configured as the Master or as Slave(1…8).
Select the total number of pedestals(master and slaves) operating in close proximity and
sharing the same ID.
Select ID(master and slaves of one system installation must share the same ID).
Only one Master can be selected with several slaves.
For example, in the library configuration shown below we have:
System A with ID = 1(M1 Master, S1 S2, S3 Slaves).
System B with ID = 2(M2 Master, S1 S2 Slaves).
The Masters are disposed as far as possible from each other not to perturb themselves.
Two different IDs are used to be sure that each slave will be synchronized with the master
from its own system.
At present, the synchronization module does not support wireless for the
time being.
5.5.3.4 Asynchronous Event Notification
Figure 5.14: Async setting