User's Guide

LSP3A Clear User’s Guide
It is only for internal use and shall not be spread without permission
29
5.5.3 Gate Options
5.5.3.1 System Type and Online Mode
Figure 5.10: System Type
There are 2 options:
LSP3A System
L-SP2+ Compatible System
The LSP3A System Mode is default mode. In L-SP2+ Compatible System mode,read tag UID
will be forced to be selected.
Figure 5.11: Online Mode
In this mode, the device will connect to the Server and when a tag is recorded, it will send the
tag information to the server and will not actively alarm. Also read tag UID option will be forced to
be selected and AFI1 Value will be forced to be 0x00(reading all tags).
Table 5.1:When the device reads the tag, the data format sent
SOF CMD_ID DATA_LEN DATA
0x1e 0x60 n Data len bytes
Example: 0x1e 0x60 0x08 0x11 0x22 0x33 0x44 0x55 0x66 0x77 0x88
Table 5.2:When the server needs the device alarm, the data format sent
SOF CMD_ID DATA_LEN
0x1e 0x51 0x00
Example: 0x1e 0x51 0x00
5.5.3.2 Alarm setting
Figure 5.12: Alarm setting