User's Guide

LSP3A Clear User’s Guide
It is only for internal use and shall not be spread without permission
17
1. Identify and mark the location of the holes to be drilled for mounting the pedestal to the ground.
The use of a tape measure and a square is recommended.
2. Drill the cable access and mounting holes according to the type of ground surface:
a. Wooden floor: Drill eight holes with a diameter of 4 mm for the mounting screws and
one hole with a diameter of 19 mm for the cable access.
b. Cement floor: Drill eight holes with a diameter of 8 mm for the cement floor plugs and
one hole with a diameter of 19 mm for the cable access. It may be necessary to provide
a groove for the power supply cable connected to the LSP3A Electronics Unit. Insert the
concrete floor plugs into the mounting holes.
Always use a protective sleeve for main power cable, which match to
the flammability grade of the product. Mains power cable must be a 3 wire
(line,neutral and earth), multi stranded copper wire, minimum section of 0.75
mm²/3A)
Figure 4.11: LSP3A Clear Bottom Plastic Cover (4 screws)
3. Remove the pedestal from the box.
4. Remove the plastic cover from the both sides after removing the 4 fixing screws.
5. Engage the power supply cable in the electric sheath and the Ethernet cable in the other
sheath (please refer to section 4.1.1 “Wire Feed Sheaths”).
6. Place the pedestal base over the mounting holes. Insert and fasten the screws in the mounting
holes according to the type of ground surface:
Wooden floor: Insert the screws directly into the mounting holes and tighten the screws in
place.
Concrete floor: Insert the screws into the concrete floor plugs and tighten the screws in
place.