Installation & Operation Manual

Table Of Contents
www.fuellock.ca November 2021 Version 3.0 Page 22
INSTALLATION FLOW TEST
Fuel Lock® devices are equipped with an on-board install/troubleshooting menu designed to assist installers and
electricians with initial install and calibration of the device, as well as field troubleshooting if hardware fails during
operation.
Note: This tool does not require any app connectivity.
The following procedure shows the calibration of custom pulse rates, as well as the verification of third-party
pulser functionality with the device.
Note: The menu is specifically designed for installers and can be accessed by using the factory
default PIN. The default PIN is 1234 if the device has not previously been connected to the mobile
app.
1.Press *Menu and enter the administrator PIN to gain access
2.Press #
3.Select #5 Install Support
4.Select #1 Tank Calibration
5.Ensure the selected port has a pulser that is physically connected to the
pulser circuit board inside the device
When first entering each Test Port menu, the screen will flash “No pulses
detected”. This indicates that the pulser connected to the pulser board is
not generating pulses (flow).
To run a test:
1.Press 0=PWR to engage power supply and turn on pumps
2.Ensure the screen is displaying a volume count
3.Repeat steps 1 and 2 on all ports with connected tanks (pulsers)
4.When volume data is displaying correctly for all tanks, connect the
device to the app.