Installation Instructions
Appendix B – Terminating Cables 
258   
Power Supply, Continued 
Procedure for 
AC power 
supply cable 
How to terminate the 3 x 0.75 mm
2
 AC power supply cable to PONE-OD67-
AC connector, proceed as follows: 
How to terminate the AC power supply cable to POE-HP-OD-AC 
power injector connector please refer to packing box installation 
instructions leaflet. 
Step 
Action 
1 
Perform the following: 
 Strip approx. 10 mm from the cable’s outer sheath (A). 
 Strip approx. 4 mm from each wire insulation (B). 
 Pass the cable through the parts of gland (C). 
 Solder the 3 pins to the connector (D) taking in consideration 
the following: 
 The Yellow/Green wire must be soldered to the pin shown 
below. 
 The remaining two black wires are for live (L) and neutral 
(N). Both wires must be soldered to the other two pins. 
There is no polarity concern regarding these two 
specific wires. 