Installation Instructions

WiBAS / WiBAS G5 Base Stations
Installation & Cabling Manual - Edition 3.2
203
Fiber Optic Cable, Continued
Procedure for
WiBAS G5
dual-BS,
continued
Step
Action
6
Install the M20 thread extension, as shown below:
Use the adjustable torque U-wrench to tighten.
Do not over tighten. Adjust the tool for max tightening
torque 6 Nm.
7
Install the remaining parts of the gland, as follows:
Install the body (M20 thread).
Do not over tighten. Adjust the tool for max tightening
torque 5 Nm.
Insert claw into the body (M20 thread).
Align the designated points. Misaligning of parts will
cause damage.
Insert the blue seal into “pressure fingers” of claw.
Position the spacer (only for metallic gland).
Screw the sealing nut. Use the adjustable torque U-wrench to
fully tighten.
Continued on next page