Installation Instructions

WiBAS / WiBAS G5 Terminal Stations
Installation & Cabling Manual - Edition 2.1
147
WiBAS OSDR-TS and Panel, Continued
Procedure,
continued
Step
Action
2
Choose the proper hose clamps of the pole adaptation packing
materials, based on the pole diameter.
3
Choose the correct position onto the pole to install the bracket.
4
Use the adjustable wrench with hexagon female bit to tighten.
Do not over tighten the M5 warm screws. Adjust the
tool for applying min 5.5 Nm and max 7 Nm tightening
torque.
5
Use the respective pole adaptation packing materials to install
the arm bracket onto the adaptation bracket, as shown below.
Use the adjustable wrench with hexagon female bit to tighten.
Do not over tighten the M8 nuts. Adjust the tool for
applying max tightening torque 15 Nm.
To continue go to step 8.
Continued on next page