Appendix B – Inband Management Connection Troubleshooting
90
Appendix B – Inband Management Connection
Troubleshooting
, Continued
Fail-safe
procedure 1
(arp-s
commands),
continued
Step Action
3
Enter the following static ARP cache entry and press ENTER:
Static ARP entry is not required when management
VLAN is assigned as default VLAN on the connection
port.
arp-s 10.255.255.254 00-05-59-64-06-33
4
Verify that you can ping the node, by entering the fail-safe IP address
and press ENTER:
ping 10.255.255.254
Echo replies should appear:
Node replies to ARP requests of fail-safe IP address
when the Ethernet link is up.
5
Access WiBAS via Node Manager by entering the fail-safe IP
address (10.255.255.254).
6 Perform a Restore Factory Default Configuration action to clear
any previous configuration on node:
i.
From the Menu, select Maintenance & Troubleshoot >
Maintenance.
ii.
In the Configuration Operations > Restore Default
Configuration
group box, select Factory and click
Restore
.
iii.
In the confirmation message that appears, click Yes. The
WiBAS returns to factory default configuration and then
reboots.
7
Login again to WiBAS , by entering the default inband IP address
(10.10.10.100/24).
End of procedure.
Continued on next page