Users Manual
WiBAS OSDR-Hub & Terminal Station / WiBAS-Connect Terminal Station
Start Up & Commissioning Manual - Edition 5.1
79
WiBAS-Connect TS (Auto-Polarization Edition), Continued
Procedure for WiBAS-Connect Auto-Polarization TS with Parabolic Low Profile Antenna,
continued
Step
Action
7 The commissioner should compare the captured values from steps 4 and 6.
• If t
he horizontal value is better than vertical then perform the steps 9 and 10.
• If the vertical value (captured on step 4) is better than horizontal then procced to
the next step.
8 Perform the following actions:
• Remove the RSSI cable from TS and after 2-3 seconds inserted again (as
described to
RSSI cable connection procedure on page 42).
• Wait 30 seconds. During boot process the voltmeter shows ~2.5 V.
Please do not perform any action till the boot process of the TS is completed.
• After boot process the TS starts automatic process scan (vertical), and:
− S/W selects F1 frequency (in horizontal polarization) and requires 10 seconds to
provide the QI value on the voltmeter.
− S/W selects F2 frequency (in horizontal polarization) and requires 10 seconds to
provide the QI value on the voltmeter.
For QI values please refer to QI table on page 93.
• Verify on the voltmeter the QI value is maintained as previous captured on step 4.
9 Permanently remove the RSSI cable and install the protection cover.
Continued on next page